The tables below detail the Series 300 Pressure and Differential Pressure (DP) ranges available.
For each Range Code the range of adjustment of the switching point is given from MIN to MAX together with the units of measurement. E.g. The setpoint adjustment for a 344P is from 0.1 to 1.4 bar.
The % RESET figure (or switching differential) is the difference in pressure that must be applied to change the output switch state from ON to OFF (or OFF to ON), and is expressed a percentage of the switch range.
There are three standard diaphragm material options 1 - nitrile, 2 - PTFE and 7 - hastelloy C. Availability of a given diaphragm material for a selected range is indicated by a *, a blank indicates the diaphragm material is not available.
There are three standard process chamber material options 1 - aluminium, 5 - 316 stainless steel and 7 - hastelloy C. Availability of a given chamber material is indicated by a number in the appropriate column for a selected range. This number is the chamber proof pressure rating in bar. A blank would indicate that the chamber material is not available, a # indicates that availability must be checked with HNL Technical Sales.
| PRESSURE RANGES (PRESSURES ARE GAUGE) | ||||||||
| SETPOINT RANGES (P and PZ) |
DIAPHRAGM MATERIAL |
CHAMBER PROOF RATING (BAR) | ||||||
|
MIN |
MAX |
UNITS |
RANGE CODE |
% RESET |
ALUMINIUM |
STAINLESS STEEL |
HASTELLOY C | |
|
1 2 7 |
1 |
5 |
7 | |||||
|
-8 -15 |
8 15 |
mBar mBar |
314PZ 315PZ |
2 |
* * * * |
|
0.5 0.5 |
|
|
-25 -50 |
25 50 |
mBar mBar |
324PZ 325PZ |
2 |
* * * * * * |
2 2 |
2 2 |
# # |
|
-125 -250 -500 |
125 250 500 |
mBar mBar mBar |
334PZ 335PZ 336PZ |
2 |
* * * * * * * * * |
10 10 10 |
10 10 10 |
# # # |
|
-0.6 -1 -1 |
0.6 1.4 6 |
Bar Bar Bar |
344PZ 345PZ 346PZ |
2 |
* * * * * * * * * |
30 30 30 |
30 30 30 |
# # # |
|
25 50 100 300 |
250 500 1200 3500 |
mBar mBar mBar mBar |
334P 335P 336P 337P |
2 |
* * * * * * * * * * * * |
10 10 10 10 |
10 10 10 10 |
# # # # |
|
0.1 0.2 0.7 2 |
1.4 3 7 21 |
Bar Bar Bar Bar |
344P 345P 346P 347P |
2 |
* * * * * * * * * * * * |
30 30 30 35 |
30 30 30 35 |
30 30 30 35 |
|
1.2 3 7 20 60 |
12 30 70 210 600 |
Bar Bar Bar Bar Bar |
354P 355P 356P 357P 358P |
3 |
* * * * * * * * * |
|
250 250 250 350 1000 |
250 250 250 350 1000 |
| DIFFERENTIAL PRESSURE RANGES (PRESSURES ARE DP) | ||||||||
| SETPOINT RANGES (DP and DPZ) |
DIAPHRAGM MATERIAL |
CHAMBER PROOF RATING (BAR) | ||||||
|
MIN |
MAX |
UNITS |
RANGE CODE |
% RESET |
ALUMINIUM |
STAINLESS STEEL |
HASTELLOY C | |
|
1 2 7 |
1 |
5 |
7 | |||||
|
-8 -15 |
8 15 |
mBar mBar |
314DPZ 315DPZ |
2.5 |
* * * * |
|
0.5 0.5 |
|
|
-25 -50 |
25 50 |
mBar mBar |
324DPZ 325DPZ |
2.5 |
* * * * * * |
2 2 |
2 2 |
# # |
|
-125 -250 |
125 250 |
mBar mBar |
334DPZ 335DPZ |
2.5 |
* * * * * * |
10 10 |
10 10 |
|
|
-100 -200 -400 |
100 200 400 |
mBar mBar mBar |
334DPZM 335DPZM 336DPZM |
3 |
* * * |
|
300 300 300 |
|
|
25 50 100 300 |
250 500 1200 3500 |
mBar mBar mBar mBar |
334DP 335DP 336DP 337DP |
2.5 |
* * * * * * * * * * * * |
10 10 10 10 |
10 10 10 10 |
# # # # |
|
20 40 100 300 |
200 400 1000 3000 |
mBar mBar mBar mBar |
334DPM 335DPM 336DPM 337DPM |
3 |
* * * * |
|
300 300 300 300 |
|
|
0.7 2 10 |
7 21 100 |
Bar Bar Bar |
346DPM 347DPM 348DPM |
3 |
*
* * |
|
300 300 300 |
|
|
| |
| Information from DATA SHEET TD300 | |