Company Products Customers Contact Home


Series 200 pressure transmitter

HNL’s Series 200 pressure transmitter uses a microprocessor to provide a 4-20mA output proportional to the input pressure. Ranges are available from 0 to 100mBar up to 0 to 1000 Bar in either gauge or absolute pressure.

The transmitter is loop powered (2 wire system) from a 24Vdc supply. The input pressure to the transmitter is applied to a metal diaphragm that transmits the pressure to the silicon pressure transducer using a silicone oil fill.

The 4-20mA output has a 5:1 turndown (i.e. the 4-20mA output may be obtained over just 20% of the pressure range of the transmitter) and the zero may be offset by up to 80% of the range.

Calibration is carried out using pushbuttons inside the enclosure. Simply apply the pressure that is required to give a 4mA output and press the green pushbutton. Then apply the pressure that is required to give a 20mA output and press the red pushbutton.

Other settings can be selected using the four DIP switches inside the enclosure as follows-

  1. Sets Output to a constant 4mA.
  2. Sets Output to a constant 20mA.
    Options 1 and 2 are for calibration but may also be used for testing of external circuit.
  3. Output signal is reversed giving a falling output current (20 - 4mA) for a rising input pressure.
  4. Applies square root extraction (generally only used on DP transmitters to provide an output proportional to flow).

Accuracy
Linearity error :
Ranges up to 10 Bar +/-0.15% typical, +/-0.35% max. Ranges above 10 Bar +/-0.15% typical, +/-0.25% max.
Temperature coefficient:
0.01% per ºC within range -20 ºC to +80 ºC.

Power Supply
Nominal power supply 24Vdc, 30mA. Minimum supply voltage 12Vdc.

Notes:
On absolute ranges the P in the range code would be replaced with PA.
For ‘Higher Proof Rating’ the P or PA in the range code would be replaced with PH or PHA.
A large number of flanged and chemical seal connections are available as special options. Please contact HNL Technical Sales for details.

Series 200 Pressure Tx

SERIES 200 RANGE CODES
RANGE CODE
PRESSURE RANGE
STD. PROOF RATING (BAR)
HIGH PROOF RATING (BAR)
225P
0 - 100mBAR
2
-
234P
0 - 200mBAR
2
-
235P
0 - 500mBAR
2.5
6
236P
0 - 1600mBAR
4
10
245P
0 - 4 BAR
7.5
16
246P
0 - 10 BAR
15
30
247P
0 - 20 BAR
30
75
255P
0 - 50 BAR
75
100
256P
0 - 160 BAR
250
-
257P
0 - 400 BAR
520
600
258P
0 - 1000 BAR
1100
-
Pressure Tx Outline Drg
   

Coding of Series 200 Pressure Transmitter

 
 
     
 
       
 
Range Code:
245P
- Use Range Code from table above
 
Housing:
1
- Classification Standard Electrical IP66
1
- Aluminium with epoxy hardended stoved enamel finish
4
- Austenitic stainless steel with self finish
1
- M20 x 1.5 ISO cable entry
 
Output:
1
- 4-20mA or 20-4mA user configurable
 
Process:
5
- 316 Stainless steel diaphragm
7
- Hastelloy C diaphragm
5
- 316 Stainless steel chamber
7
- Hastelloy C chamber
0
3
- 1/4" NPT INT. connection
0
6
- 1/2" NPT INT. connection
0
8
- 1/2" NPT Male connection

  Information from DATA SHEET TD200 ELC